24/7
Continuous monitoring
Local and cloud records are synchronized day and night.
≥36 months
Data retention
Long-term storage of operation records both locally and in the cloud
4 channels
Notification method
App / WhatsApp / SMS / Email
<1 minute
Alarm Delay
An anomaly triggered multi-channel communication
Subdividing application scenarios
Commercial buildings / Industrial parks
Centralized monitoring of central air conditioning room, water pump room, power transformer room and elevator room.
hotel
Ensure the stable operation of hot and cold water, air conditioning, and logistical equipment to maintain the guest experience.
Chain store management
The status of equipment across branches is uniformly visible, allowing headquarters to remotely monitor operations at each location.
Residential and community facilities
Operation monitoring of shared facilities such as water supply pumps, fire pumps, and generators.
In properties lacking a building management system (BMS) or with insufficient BMS coverage, critical electromechanical equipment is often scattered across different server rooms, lacking unified monitoring. Anomalies are mostly discovered through regular manual inspections, often only becoming apparent after they have already broken down, leading to sudden shutdowns, abnormal energy consumption, and increased emergency maintenance costs.
-
Equipment is scattered, there is no BMS, or the BMS does not cover older equipment.
-
Relying on manpower for regular patrols means abnormalities are discovered too late.
-
Fault records are scattered, making it difficult to trace responsibility and the effectiveness of maintenance.
-
Unexpected outages impact tenant experience and property reputation.
FAQ
VITEG uses iBSMon as its core, connecting cooling towers, water pumps, power equipment, electromechanical rooms, and other critical equipment to a single monitoring platform. Through edge data acquisition, real-time dashboards, and multi-channel alarms, it transforms passive inspections into proactive prevention and automatically generates auditable operational reports.
Our solution
Monitoring objects
Cooling tower (fans, water level, temperature)
Refrigeration/Hot Water Pumps and Circulation Pumps
Power equipment (main switch, distribution box, current load)
Air conditioning unit and fan cabinet
Generators and fire pumps
Elevator machine room environment

End-to-end workflow
01
02
03
04
05
Access and Acquisition
VITEG Gateway digitizes signals from field devices through interfaces such as dry contacts, Modbus, and pulses.
Edge treatment
Data processing and threshold determination are completed locally, and monitoring and recording can continue even if the network is interrupted.
Instant Kanban
Administrators can view device status, operating trends, and historical curves at any time through the app or website.
Abnormal warning
When exceeding the standard or abnormal trends are detected, notifications will be sent immediately via App, WhatsApp, SMS or email.
Report generation
It automatically aggregates operating hours, abnormal events, and performance indicators, and outputs auditable digital reports.
Deployment mode
Cloud deployment: Data is uploaded to the cloud server in real time for 24/7 monitoring and long-term storage.
Local deployment: All data is collected, processed, and stored on-site, making it suitable for high-security scenarios.
Hybrid deployment: Local processing + cloud push alerts, balancing data security and remote convenience.